Patient Monitor







Venus F15 Multi-parameter Monitor
Structure chart:
|
Physical Specifications
|
||||
|
Dimension and weight
|
Dimension
|
330(W) * 260(H) * 140(D) mm
|
||
|
Weight
|
standard configuration: 4 kg
|
|||
|
Operation environment
|
Power requirements
|
AC 100-220V, 50/60HZ, 60W
|
||
|
Power
|
90VA
|
|||
|
Temperature
|
5-40℃
|
|||
|
Humidity
|
30-93% non-condensing
|
|||
|
Safety
|
Meet the requirements of IEC60601 series
|
|||
|
Patient range
|
Adult, neonate and pediatric patients
|
|||
|
Performance Specification
|
||||
|
Display
|
15' color TFT LCD screen, support external VGA (optional). rolling and refreshing waveform display
|
|||
|
Display mode
|
Standard, large font, NIBP trend, trend table, full lead ECG, Oxy CRG.
|
|||
|
Interface
|
Parameter cable interface
AC power input socket
Network interface
External VGA interface for connection of alternate display
|
|||
|
Battery
|
1 external rechargeable lithium battery , 4.5 Ah 12V
|
|||
|
Alarm indicator
|
Visual on-display and integrated alarm light
Audible alarm and personated voice reminding alarm
|
|||
|
Data storage
|
720 hours monitoring data
10000 NIBP records storage
1000 alarm event.
|
|||
|
Printer
|
Built-in 50mm thermal printer (option),
2 traces, print speed 25mm/s & 50mm/s
print width:50mm
|
|||
|
Net working
|
Support connection to central monitoring station through LAN (TCP/IP) or wireless connection
|
|||
|
ECG
|
||||
|
Leads type
|
5-lead : I, II, III, aVR, aVL, aVF, V
|
|||
|
Sweep speed
|
12.5mm/s, 25mm/s
|
|||
|
Gain selection
|
×0.5, ×1, ×2
|
|||
|
ECG waveform
|
2 channels
|
|||
|
Operation mode
|
Diagnostic, monitor, surgery
|
|||
|
Heart rate range
|
0 -300bpm
|
|||
|
Accuracy
|
1bpm or ±1% whichever is greater
|
|||
|
Alarm range
|
Audible and visual alarm, adjustable
|
|||
|
ST/ arrhythmia
|
Real time S-T segment detection, pace detection and arrhythmia analysis
|
|||
|
Protection
|
Against electrosurgical interference and defibrillation
|
|||
|
Respiration (RESP)
|
||||
|
Method
|
Thoracic impedance
|
|||
|
Operation mode
|
Auto/manual
|
|||
|
Measurement range
|
Adult: 0-120BrPM; neonatal /pediatric: 0-150BrPM
|
|||
|
Apnea alarm
|
Yes
|
|||
|
Alarm
|
Yes, audible and visual alarm ,alarm events recallable
|
|||
|
NIBP
|
||||
|
Method
|
Automatic oscillometric
|
|||
|
Operation mode
|
Manual/Automatic/STAT
|
|||
|
Auto measure time
|
Adjustable
|
|||
|
Measurement unit
|
mmHg /kPa selectable
|
|||
|
Test interval
|
1-480 minutes
|
|||
|
Measurement range
|
Adult: 10-300 mmHg ;
Child: 10-240 mmHg ;
Infant: 10-150 mmHg
|
|||
|
Over-pressure protection
|
Double safety protection
|
|||
|
Accuracy of blood pressure measurement
|
The mean error shall be less than±5mmHg
the standard deviation shall be less than 8mmHG
|
|||
|
Resolution
|
1 mmHg
|
|||
|
SpO2
|
||||
|
Measurement range
|
0%-100%
|
|||
|
Resolution
|
1%
|
|||
|
Accuracy
|
±2% (70-100%, adult/pediatric, non-motion )
±3% (70-100%, neonate, non-motion )
±3% (70-100%, adult/pediatric/neonate, motion )
0-69% unspecified
|
|||
|
Alarm range
|
1-100%
|
|||
|
Pulse rate
|
Pulse range:
|
20-300bpm
|
||
|
Accuracy:
|
±3bpm(non-motion)
±5bpm(motion )
|
|||
|
Temperature (TEMP)
|
||||
|
TEMP range
|
0-50℃
|
|||
|
Resolution
|
0.1 ℃
|
|||
|
Accuracy
|
±0.1℃ (excluding the sensor)
|
|||
|
Channel
|
Dual-channel. Provide T1;T2; △T
|
|||
|
IBP
|
||||
|
Measurement range
|
-50-360mmHg
|
|||
|
Channel
|
2 channels
|
|||
|
Pressure transducer
|
Sensitive :5u V/V mmHg
Impedance range :300-3000 Ω
|
|||
|
Pressure names
|
ART,PA,CVP,RAP,LAP,ICP,P1,P2
|
|||
|
Alarm range
|
-10-300 mmHg
|
|||
|
PR from IBP
|
Range & Accuracy:
|
25-200bpm ±1bpm or ±1bpm which is greater
201-350bpm ±2%
|
||
|
Resolution :
|
1bpm
|
|||
|
Depth of Anesthesia (BIS)
|
||||
|
EEG sensitivity
|
+/- 475μV
|
|||
|
Noise
|
< 2uVp-p (1-150 Hz)
|
|||
|
CMRR
|
> 100 dB
|
|||
|
Input impedance
|
> 50Mohm
|
|||
|
Sample rate
|
1024 samples/s, 16 bits
|
|||
|
Index and display update
|
IoC 0-99, filter 1-47 Hz, 1 sec. display update
|
|||
|
EEG waveform
|
± 500 µV scaleable, filter 1–30 Hz, 3 sec. window length.
|
|||
|
ESR
|
0-100%
|
|||
|
EMG 0-100 arbitrary unit
|
Curve and bar
|
|||
|
Index trend
|
5 min and 60 min
|
|||
|
Digital output
|
Wireless BT interface (RFCOMM). 10 meters range
|
|||
|
Alarms
|
IoC high and low user selectable limits
|
|||
|
Artifact rejection
|
Automatic. user can disable.
|
|||
|
Sensor impedance range
|
0 – 14kohm
|
|||
|
EtCO2 (Side stream CO2)
|
||||
|
Measurement range
|
0-99mmHg
|
|||
|
Accuracy
|
±2mmHg(0-40mmHg)
±5% of reading(41-76mmHg)
±10% of reading (77-99mmHg)
|
|||
|
Resolution
|
1mmHg
|
|||
|
Sampling rate
|
70m1/min 100m1/min
|
|||
|
Sampling rate accuracy
|
0.15 or 15m1/min
|
|||
|
Start-up time
|
30 Sec. the module enters the warming up status after the start up.
1 minute later, it enters the ready-to-measure status.
|
|||
|
Respiration rate
|
3-150 rpm
|
|||
|
Respiration rate accuracy
|
±2BrPM (0-70BrPM)
±5BrPM (>70BrPM)
|
|||
|
Response time
|
When measured with a neonatal water trap and a 2.5 m-long neonatal sampling line:
< 3.5 s @ 100 ml/min
<4 s @ 70 ml/min
|
|||
|
When measured with an adult water trap and a 2.5 m-long adult sampling line:
<5.5 s @ 100 ml/min
<7 s @ 70 ml/min
|
||||
|
Delay time
|
When measured with a neonatal water trap and a 2.5m-long neonatal sampling line:
<3 s @ 100 ml/min
<3.5 s @ 70 ml/min
|
|||
|
When measured with an adult water trap and a 2.5m-long adult sampling line:
<5 s @ 100 ml/min
<6.5 s @ 70 ml/min
|
||||
|
Multi-Gas/O2
|
||||
|
Method
|
Infrared absorption
|
|||
|
Gas sorts
|
CO2, N2O, Des, Iso, Enf, Sev, Hal, O2,
(Optional paramagnetic sensor)
|
|||
|
Measurement range
|
CO2: 0~30%
N2O : 0~105%
O2, :0~105%
Enf, Iso, Hal: 0~30%
Sev: 0~30%
Des:0~30%
|
|||
|
Data output
|
Fi and ET values
|
|||
|
Respiration rate
|
±1BrPM(2~60BrPM)
61~100BrPM (unspecified)
|
|||
|
Other
|
Up to 4 waveforms displayed
Agent mixture detection
MAC value displayed
|
|||